Re: dB SPL to dBA (Torben Poulsen )


Subject: Re: dB SPL to dBA
From:    Torben Poulsen  <tp(at)DAT.DTU.DK>
Date:    Wed, 20 May 1998 16:29:06 +0200

On dB SPL to dBA Here are the numbers for A, C and D-filter Freq A C D 10 -14.3 -26.6 12.5 -63.4 -11.2 -24.6 16 -56.7 -8.5 -22.6 20 -50.5 -6.2 -20.6 25 -44.7 -4.4 -18.7 31.5 -39.4 -3 -16.7 40 -34.6 -2 -14.7 50 -30.2 -1.3 -12.8 63 -26.2 -0.8 -10.9 80 -22.5 -0.5 -9 100 -19.1 0.3 -7.2 125 -16.1 -0.2 -5.5 160 -13.4 -0.1 -4 200 -10.9 0 -2.6 250 -8.6 0 -1.6 315 -6 0 -0.8 400 -4.8 0 -0.4 500 -3.2 0 -0.3 630 -1.9 0 -0.5 800 -0.8 0 -0.6 1000 0 0 0 1250 0.6 0 2 1600 1 -0.1 4.9 2000 1.2 -0.2 7.9 2500 1.3 -0.3 10.4 3150 1.2 -0.5 11.6 4000 1 -0.8 11.1 5000 0.5 -1.3 9.6 6300 -0.1 -2 7.6 8000 -1.1 -3 5.5 10000 -2.5 -4.4 3.4 12500 -4.3 -6.2 1.4 16000 -6.6 -8.5 -0.7 20000 -9.3 -11.2 -2.7 freq. A C D Torben Poulsen, Department of Acoustic Technology Building 352, Technical University of Denmark DK-2800 Lyngby, Denmark Voice: +45 4525 3940 (direct); +45 4588 1622 (Departm.) Fax: +45 4588 0577 E-mail: tp(at)dat.dtu.dk http://www.dat.dtu.dk/